Applied Bolting
the best way to bolt!
1-800-552-19991-802-460-3100
Search 
Home
Sitemap
Contact
Downloads
Videos
  • Company
    • About

    • News

    • Events

    • Distributors

    • Careers

  • Products
    • Squirter® DTIs

    • Cost Analysis
    • Why Use Squirter® DTIs
    • Who's Using Squirter® DTIs
    • Squirter® DTI Testimonials
    • Standard DTIs

    • Standard® DTI Testimonials
    • Wind Squirter® DTIs

    • Special DTIs

    • DTI Sandwiches
    • Squirter® DTIs for Pipe Flange Bolting
    • Lubricants

    • Wrenches

    • How To Buy / Distributors

    • Line Card

    • Specifications

    • Bolt Tension Chart
    • Application Specifications
    • Manufacturing Specifications
  • Field Support
    • Training

    • Quality Assurance

    • Service & Field Support Testimonials

    • Warranty, Patents and Trademark

  • Projects & Applications
    • Wind Power

    • Bridges

    • Power Plants

    • Commercial

    • Sports Facilities

    • Industrial and Process

    • Scrubbers and Precipitators

    • Original Equipment

    • Special Projects

  • Bolting Resources
    • FAQs (Squirter® DTIs)

    • FAQs (Standard DTIs)

    • Flat Washer Chart

    • Quality Assurance

    • Manufacturing Specs

    • Application Specs

    • Roadmap to Applied Bolting Certs

    • Cost Analysis

    • Downloads

    • View All Downloads
    • Trial Projects
    • Articles
    • Install/Inspect Instructions
    • .dxf/.dwg's for Detailers
    • eDrawings
    • PowerPoint
    • Spanish Instructions
    • Videos
    • Torque / Wrench Capacity Chart
    • Flat Washer Chart
    • SS-39D Orange Silicone MSDS
    • RTV 200-185 Orange Silicone MSDS
    • Our Brochure
    • Videos

    • DTIs and Squirter® DTIs for Engineers
    • DTIs and Squirter® DTIs for Inspectors
    • DTI and Squirter® DTI definitions
    • Torque Isn't Tension
    • Squirter® DTI calibration
    • NEW: Preinstallation Verification Test
    • NEW: Job Inspection Gap
    • NEW: Bolt Assembly Nut Side
    • NEW: Bolt Assembly Head Side
    • Can't Squash the Bumps? Dry or Rusty Bolts
    • Squirter® DTIs and Oversized Holes
    • Squirter® DTIs in Cold Weather Conditions
    • NEW: Hot Dip and Mechanically Galvanized Fasteners
    • Bolting Articles

    • Bolt and DTI Coating
    • Torque and Tension
    • Squirter® DTIs
    • DTIs
    • Interactive 3D Technology
    • Wind Power
    • Various Bolting Articles
    • Bolting Methods

    • Calibrated Wrench
    • Direct Tension Indicator
    • Turn of Nut (Part Turn)
    • Twist-Off Bolts
    • University Studies and Independent Research

  • Installation & Inspection
    • Installing Squirter® DTIs

    • Installing Standard DTIs

    • Installing Windpower Squirter DTIs

    • Spanish Instructions

    • Chinese Instructions

    • Training Videos

    • Application Advisories

    • 1 1/4" Dia. A490 Bolts in oversized holes
    • SQUIRTER® DTIs and oversized holes
    • Oversized Holes: Flat Washer Chart
    • Hot Dip Galvanized Flat Washers
    • Using Nut End Installation with 1 1/4" diameter or Larger DTI's
    • Weathering Steel DTI's on Bridges
    • Skidmore MZ Plate Bore for A490 DTIs
    • Bolting Methods

    • Calibrated Wrench
    • Direct Tension Indicator
    • Turn of Nut (Part Turn)
    • Twist-Off Bolts
    • All the Details (the fine print)

    • Short Form DTI Install

Most viewed: Bolt Torque Requir..., Bolt Tension Requi..., Flat Washer Chart ...
recently viewed: Downloads: Install..., Downloads: Recomme..., DTIs Use and Speci...
  • Squirter® DTIs
  • Standard DTIs
  • Wind Squirter® DTIs
  • Special DTIs
    • DTI Sandwiches
    • Squirter® DTIs for Pipe Flange Bolting
  • Lubricants
  • Wrenches
  • How to Buy / Distributors
  • Testimonials
  • Specifications
  • Line Card

Squirter ® DTIs for Pipe Flange Bolting

B7 studs in pipe flange bolting situations demand careful tightening technique, usually sequentially staged tightening in a star pattern around the flange, usually done using torque values. Now it is possible to use Squirter DTI’s, custom engineered to squirt reliably at 60% of the stud’s yield strength. Brought up to final “squirt” in stages, and when finished with all the squirted silicone volume and appearance the same around the flange, the pipe installers will know the tensions in all the studs are the same, regardless of torque resistance, coatings, etc.

Caution -- Pipe flanges must have bolt holes that are no larger than 1/16” over the nominal diameter of the stud for squirters to work correctly. If not, then we will supply a correctly made bedding flat washer for use under the squirter. On top of the squirter bumps, of course, between the nut and the squirter bumps, must be a correctly hardened flat washer. If that is not available at site, we will supply that also.

For more information:
contact Mr. Wayne Wallace, President of Applied Bolting, 800-552-1999, or click here to see Squirter® DTI's

  • COMPANY
  • PRODUCTS
  • FIELD SUPPORT
  • PROJECTS & APPLICATIONS
  • BOLTING RESOURCES
  • INSTALLATION & INSPECTION
Squirter DTI's & Squirters DTI are Registered Trademarks of Applied Bolting Technology Products, Inc.
1413 Rockingham Road Bellows Falls, Vermont, USA 05101
©2012 Applied Bolting Technology
site by integritive web design, asheville