Applied Bolting
the best way to bolt!
1-800-552-19991-802-460-3100
Search 
Home
Sitemap
Contact
Downloads
Videos
  • Company
    • Who We Are

    • News

    • Events

    • Distributors

    • Careers

  • Products
    • Squirter® DTIs

    • Cost Analysis
    • Why Use Squirter® DTIs
    • Who's Using Squirter® DTIs
    • Squirter® DTI Testimonials
    • Standard DTIs

    • Standard® DTI Testimonials
    • Wind Squirter® DTIs

    • Special DTIs

    • DTI Sandwiches
    • Squirter® DTIs for Pipe Flange Bolting
    • Lubricants

    • Wrenches

    • How To Buy / Distributors

    • Line Card

    • Specifications

    • Bolt Tension Chart
    • Application Specifications
    • Manufacturing Specifications
  • Field Support
    • Training

    • Quality Assurance

    • Service & Field Support Testimonials

    • Warranty, Patents and Trademark

    • Tell us about your Job

  • Projects & Applications
    • Wind Power

    • Bridges

    • Power Plants

    • Commercial

    • Sports Facilities

    • Industrial and Process

    • Scrubbers and Precipitators

    • Original Equipment

    • Special Projects

  • Bolting Resources
    • FAQs (Squirter® DTIs)

    • FAQs (Standard DTIs)

    • Flat Washer Chart

    • Quality Assurance

    • Manufacturing Specs

    • Application Specs

    • Roadmap to Applied Bolting Certs

    • Cost Analysis

    • Downloads

    • View All Downloads
    • Trial Projects
    • Articles
    • Install/Inspect Instructions
    • .dxf/.dwg's for Detailers
    • PowerPoint
    • Spanish Instructions
    • Videos
    • Torque / Wrench Capacity Chart
    • Flat Washer Chart
    • SS-39D Orange Silicone MSDS
    • RTV 200-185 Orange Silicone MSDS
    • Our Brochure
    • Videos

    • DTIs and Squirter® DTIs for Engineers
    • DTIs and Squirter® DTIs for Inspectors
    • DTI and Squirter® DTI definitions
    • Torque Isn't Tension
    • Squirter® DTI calibration
    • NEW: Preinstallation Verification Test
    • NEW: Job Inspection Gap
    • NEW: Bolt Assembly Nut Side
    • NEW: Bolt Assembly Head Side
    • Can't Squash the Bumps? Dry or Rusty Bolts
    • Squirter® DTIs and Oversized Holes
    • Squirter® DTIs in Cold Weather Conditions
    • NEW: Hot Dip and Mechanically Galvanized Fasteners
    • Bolting Articles

    • Bolt and DTI Coating
    • Torque and Tension
    • Squirter® DTIs
    • DTIs
    • Interactive 3D Technology
    • Wind Power
    • Various Bolting Articles
    • Bolting Methods

    • Calibrated Wrench
    • Direct Tension Indicator
    • Turn of Nut (Part Turn)
    • Twist-Off Bolts
    • University Studies and Independent Research

  • Installation & Inspection
    • Installing Squirter® DTIs

    • Installing Standard DTIs

    • Installing Windpower Squirter DTIs

    • Spanish Instructions

    • Chinese Instructions

    • Training Videos

    • Application Advisories

    • 1 1/4" Dia. A490 Bolts in oversized holes
    • SQUIRTER® DTIs and oversized holes
    • Oversized Holes: Flat Washer Chart
    • Hot Dip Galvanized Flat Washers
    • Using Nut End Installation with 1 1/4" diameter or Larger DTI's
    • Weathering Steel DTI's on Bridges
    • Skidmore MZ Plate Bore for A490 DTIs
    • Bolting Methods

    • Calibrated Wrench
    • Direct Tension Indicator
    • Turn of Nut (Part Turn)
    • Twist-Off Bolts
    • All the Details (the fine print)

    • Short Form DTI Install

Most viewed: Bolt Torque Requir..., Bolt Tension Requi..., Flat Washer Chart ...
recently viewed: Designer Benefits ..., Chinese Installati..., Bolting Method: Ca...
  • Squirter® DTIs
    • Cost Analysis
    • Why Use Squirter® DTIs
      • Inspector Benefits
      • Erector Benefits
      • Designer Benefits
      • Owner Benefits
      • Detailers
      • Fabricator Benefits
      • EPC Contractor Benefits
      • OEM Builder Benefits
      • Squirter DTIs and Constructability
    • Who's Using Squirter® DTIs
  • Standard DTIs
  • Wind Squirter® DTIs
  • Special DTIs
  • Lubricants
  • Wrenches
  • How to Buy / Distributors
  • Testimonials
  • Specifications
  • Line Card

Detailers

Detailer are generally indifferent as to whether DTI's or SQUIRTER® DTIs are going to be used. If the design calls for DTI's there are a few matters that the detailer must address, however.

  1. Bolt Length - DTI's don't change the ordered length of bolts because all bolts are sized to have a few threads sticking through the nut, and the DTI takes up less than the length of two threads. DTI thickness is shown on the chart located under manufacturing specifications For more detailed information on DTI's and bolt lengths please see this FAQ
  2. Flat Washer Requirements - for more on flat washer requirements
    • APPLICATION ADVISORY: Flat Washer Requirements Chart
    • APPLICATION ADVISORY: Hot Dip Galvanizing of Flat Washers Caution
    • APPLICATION ADVISORY: 1 1/4" diameter A490 Bolts in oversized holes
    • FAQ: DTIs compress but no squirt event
    • FAQ: Flat Washer Requirements
    • EDRAWINGS
  3. .DWG / .DXF AutoCAD files for Structural Steel Detailers: you can put them on your project drawings, then annotate them a little, which then tells bidders of that project to expect DTI's on the bolts and how to install them.
    Click Here For DWG / DXF files for Detailers
  • COMPANY
  • PRODUCTS
  • FIELD SUPPORT
  • PROJECTS & APPLICATIONS
  • BOLTING RESOURCES
  • INSTALLATION & INSPECTION
Squirter DTI's & Squirters DTI are Registered Trademarks of Applied Bolting Technology Products, Inc.
1413 Rockingham Road Bellows Falls, Vermont, USA 05101
©2012 Applied Bolting Technology
site by integritive web design, asheville